Static Transfer Switch (STS)
Reliable Transfers, Continuous Power.
Hyper Static Transfer Switch (STS) units are engineered to deliver seamless power transfer and exceptional reliability for Enterprise, Cloud, and AI Data Centers. Designed with capacities ranging from 600A to 1200A in 3-pole and 4-pole configurations, these units provide critical power continuity and advanced features to support mission-critical environments.
Built to the highest standards, Hyper STS units combine innovative engineering, precision manufacturing, and ISO-9001 certified quality to deliver seamless power transfer solutions for modern data centers. Whether for Enterprise, Cloud, or AI applications, Hyper STS units ensure uptime, safety, and performance in mission-critical environments.
- Capacity Range: Supports power loads from 600A to 1200A, ensuring scalability and reliability for diverse data center requirements.
- 3-Pole and 4-Pole Support: Accommodates varied electrical configurations for maximum flexibility.
- Full Busbar Construction: Enhances system reliability, safety, and simplified maintenance with robust design.
- Agnostic Molded Case Switch Options: Ensures compatibility with a wide range of switch technologies to meet specific operational needs.
- Full Front Access: Simplifies installation, operation, and maintenance, reducing downtime and improving serviceability.
- Top or Bottom Feeder Entry/Exit: Offers installation flexibility to suit unique facility layouts.
- Compartmentalized High-Quality Construction: Provides enhanced safety and operational efficiency by isolating critical components.
- Optional Real-Time Thermal Imaging: Enables proactive monitoring of thermal conditions, improving reliability and preventing potential failures.
Category | Specification | Specification Detail |
---|---|---|
General | Power Semiconductors: | Fully Rated |
Cooling: | Redundant Fans with Failure Sense | |
Construction: | Full Busbar – Copper | |
Deadfront: | Bolt On | |
Cable Paths: | Top/Bottom Entry/Exit | |
Power Supplies: | Triple Redundancy | |
Control Logic: | Dual Microprocessor PCBs Redundant SCR Drivers | |
Surge Protection: | Optional: Up to 100 kA on each source | |
Output Load Switches: | Redundant | |
Protection: | Molded Case Switches (6 switch standard, 5 switch option) | |
Brands: | Siemens, Schneider Electric | |
Communications | Alarm Relays: | 4 |
Building Alarm Inputs: | 2 | |
EPO: | Bolt | |
Communications: | Modbus TCP/IP | |
Service Port: | RS232 | |
Event Alarm Log: | 1000 Events | |
Electrical | Voltage: | 480V |
Frequency: | 60 Hz | |
Current: | 600A, 800A, 1000A/1200A (Q4 2025) | |
Short Circuit Withstand: | 65 and 100 kAIC options | |
Input/Output: | 3-phase, 3-wire + ground (600A, 800A) 3-phase, 4-wire + ground (600A) | |
Overload Capacity: | 110% for 60 minutes 125% for 30 minutes 150% for 2 minutes | |
Switching | Synchronized Transfer Time: | 5 ms |
Non-synchronized Transfer Time: | 16 ms | |
Controller Rate /Cycle: | 400 microsecond | |
Metering | Integrated Metering: | Yes |
Waveform Capture: | Yes, three-line voltages (V1, V2 & V3) and line currents (I1, I2 & I3) with time stamps | |
Standards | UL: | UL 1008S |
Enclosure Type: | NEMA Type 1 | |
EMC: | C2 category IEC 62310-2, FCC part 15 | |
Environmental | Operating Temperature: | 0 to +40°C (32 to +104°F), up to 50°C with derating |
Storage Temperature: | -25 to +70°C (-13 to +158°F) | |
Maximum Relative Humidity (non-condensing): | 95% | |
Maximum Altitude without Derating: | 3280 ft / 1000 m a.s.l. | |
Acoustic Level at 3.28 ft / 1m (ISO 3746): | ≤ 60 dBA | |
Dimensions (WxDXH): | 600A: | 68″ x 42″ x 90″ |
800A: | 68″ x 42″ x 90″ |